Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
2.
Cell Transplant ; 29: 963689720947098, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32749147

RESUMO

Here, we present a case that required a supplemental "old school" islet purification for a safe intraportal infusion. Following pancreas procurement from a brain-dead 26-year-old male donor (body mass index: 21.9), 24.6 ml of islet tissue was isolated after continuous density gradient centrifugation. The islet yield was 504,000 islet equivalent (IEQ), distributed among the following three fractions: 64,161 IEQ in 0.6 ml of pellet, 182,058 IEQ in 10 ml, and 258,010 IEQ in 14 ml with 95%, 20%, and 10% purity, respectively. After a 23-h culture, we applied supplemental islet purification, based on the separation of tissue subfractions during unit gravity sedimentation, a technique developed over 60 years ago ("old school"). This method enabled the reduction of the total pellet volume to 11.6 ml, while retaining 374,940 IEQ with a viability of over 90%. The final islet product was prepared in three infusion bags, containing 130,926 IEQ in 2.6 ml of pellet, 108,079 IEQ in 4 ml of pellet, and 135,935 IEQ in 5 ml of pellet with 65%, 40%, and 30% purity, respectively, and with the addition of unfractionated heparin (70 units/kg body weight). Upon the islet infusion from all three bags, portal pressure increased from 7 to 16 mmHg. Antithrombotic prophylaxis with heparin was continued for 48 h after the infusion, with target activated partial thromboplastin time 50-60 s, followed by fractionated heparin subcutaneous injections for 2 weeks. ß-Cell graft function assessed on day 75 post-transplantation was good, according to Igls criteria, with complete elimination of severe hypoglycemic episodes and 50% reduction in insulin requirements. Time spent within the target glucose range (70-180 mg/dl) improved from 42% to 98% and HbA1c declined from 8.7% to 6.7%. Supplemental "old school" islet purification allowed for the safe and successful utilization of a robust and high-quality islet preparation, which otherwise would have been discarded.


Assuntos
Separação Celular/métodos , Transplante das Ilhotas Pancreáticas/métodos , Adulto , Humanos , Masculino
3.
Adv Med Sci ; 64(2): 324-330, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31003201

RESUMO

PURPOSE: Hepatic alveolar echinococcosis (AE) is a parasitic disease caused by the larval stage of the tapeworm Echinococcus multilocularis. Ultrasonography is the method of choice in the initial diagnosis of AE. The aim of the study is to present the most frequent sonomorphological patterns of lesions in hepatic AE based on the analysis of ultrasound findings in patients treated for AE at the University Centre of Maritime and Tropical Medicine (UCMMiT; Gdynia, Poland), and to establish whether there is a relationship between the clinical stage of AE and the occurrence of a specific sonomorphological pattern of hepatic lesions. PATIENTS AND METHODS: We analysed the results of ultrasound examinations of 58 patients hospitalized in the UCMMiT with probable or certain diagnosis of AE. Liver lesions were assessed according to the classification developed by researchers from the University Hospital in Ulm (Germany). Statistical analysis was based on the relationship between the occurrence of a specific sonomorphological pattern of hepatic lesions and the clinical stage of AE. RESULTS: The most frequently observed patterns of AE lesions in the liver were the hailstorm and the pseudocystic patterns. There was no correlation between the clinical stage of the disease and the ultrasonographic appearance of lesions. There was no statistically significant relationship between the more frequent occurrences of specific ultrasonographic patterns of lesions in the liver and radical or non-radical surgery. CONCLUSIONS: The ultrasonographic appearance of the lesion in liver AE cannot determine the therapeutic management. Treatment plan should be established based on the PMN classification.


Assuntos
Equinococose Hepática/diagnóstico por imagem , Equinococose Hepática/patologia , Ultrassonografia/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Adulto Jovem
4.
Blood Press ; 27(5): 304-312, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29742971

RESUMO

BACKGROUND: Primary aldosteronism (PA) is the most common cause of secondary hypertension and bilateral adrenal hyperplasia (BAH) and aldosterone-producing adenoma (APA) seem to be the most common causes of PA. Unilateral adrenalectomy (UA) is the preferred treatment for APA, although the benefits are still difficult to assess. CASE REPORT: We present a case report of a 69-year old man with a 30 year history of hypertension and probably long-standing PA due to APA, with typical organ complications. Since repeated abdominal CT scans were equivocal, not showing radiological changes characteristic for PA, the diagnosis of APA was delayed and was only finally confirmed by adrenal venous sampling which demonstrated unilateral aldosteronism. The patient underwent UA, complicated by mineralocorticoid deficiency syndrome and increased creatinine and potassium levels. At 12 months follow-up the patient still had hyperkalemia and was fludrocortisone dependent. CONCLUSIONS: Older patients and patients with long-lasting PA who are treated with UA may demonstrate deterioration of renal function and develop transient or persistent insufficiency of the zona glomerulosa of the remaining adrenal gland necessitating fludrocortisone supplementation. Transient hyperkalemia may be observed following UA as a result of the prolonged effects of aldosterone antagonists and/or transient mineralocorticoid/glucocorticoid insufficiency. Additionally, the level of progression of chronic kidney disease after UA is difficult to predict. There likely exists a group of patients who might paradoxically have higher cardiovascular risk due to significant deterioration in kidney function not only resulting from the removal of the aldosterone induced glomerular hyperfiltration phenomenon. Identification of such a group requires further detailed investigation.


Assuntos
Córtex Suprarrenal/fisiopatologia , Adrenalectomia/efeitos adversos , Insuficiência Renal/etiologia , Zona Glomerulosa/fisiopatologia , Idoso , Anti-Inflamatórios , Fludrocortisona/uso terapêutico , Humanos , Hiperaldosteronismo/complicações , Hiperpotassemia/etiologia , Hipertensão/complicações , Masculino
5.
Can J Gastroenterol Hepatol ; 2017: 5478068, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29090208

RESUMO

PURPOSE: 11C-Acetate is radiotracer being considered an alternative to 18F-fluorodeoxyglucose. Evaluation of 11C-acetate biodistribution in human parenchymal organs is described. METHODS AND MATERIALS: 60 consecutive patients referred to 11C-acetate PET CT suspected of renal or prostate cancer relapse with negative results (no recurrent tumor) were included in the study. Acquisition from the base of skull to upper thigh was made 20 min after i.v. injection of 720 MBq of 11C-acetate. The distribution was evaluated by measuring the uptake in pancreas (uncinate process and body separately), liver, spleen, and left suprarenal gland. Clinical data of included patients showed no abnormalities in these organs. RESULTS: Biodistributions of 11C-acetate radiotracer were compared in different organs. Standardized uptake values of 11C-acetate were significantly higher in pancreatic parenchyma (SUV mean 6,4) than in liver (SUV mean 3,3), spleen (SUV mean 4,5), or suprarenal gland (SUV mean 2,7) tissues. No significant difference was found between pancreatic head (SUV mean 6,4) and body (SUV mean 5,9) uptake. In case of all aforementioned organs, there were no differences either between both sexes or between formerly diagnosed tumors (renal and prostate). CONCLUSIONS: Evaluation of 11C-acetate uptake differences in parenchymal organs will allow establishing normal patterns of distribution. High pancreatic uptake may be used in quantitative assessment of organ function in diffuse nonneoplastic pathology.


Assuntos
Acetatos/administração & dosagem , Carbono/administração & dosagem , Tomografia por Emissão de Pósitrons/métodos , Compostos Radiofarmacêuticos/administração & dosagem , Acetatos/farmacocinética , Glândulas Suprarrenais/diagnóstico por imagem , Carbono/farmacocinética , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pâncreas/diagnóstico por imagem , Compostos Radiofarmacêuticos/farmacocinética , Baço/diagnóstico por imagem , Distribuição Tecidual
7.
Ginekol Pol ; 85(7): 545-8, 2014 Jul.
Artigo em Polonês | MEDLINE | ID: mdl-25118509

RESUMO

Metastatic lesions within the ovary constitute a serious diagnostic problem in daily practice. We present an interesting case of Krukenberg tumor in a woman 13 years after partial gastrectomy due to stomach cancer. Our case confirms that every woman with history of cancer should remain under gynecological control. It is important due to a high risk of metastatic changes localized in the ovaries, regardless of the time elapsed since the diagnosis of the primary tumor


Assuntos
Tumor de Krukenberg/diagnóstico por imagem , Tumor de Krukenberg/secundário , Neoplasias Ovarianas/diagnóstico por imagem , Neoplasias Ovarianas/secundário , Neoplasias Gástricas/cirurgia , Feminino , Gastrectomia , Humanos , Pessoa de Meia-Idade , Neoplasias Gástricas/patologia , Resultado do Tratamento , Ultrassonografia
8.
Pol J Radiol ; 79: 175-80, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25006355

RESUMO

BACKGROUND: Patients with pathological tissue mass in thoracic cage found with imaging require histopathological or cytological confirmation of malignancy before treatment. The tissue material essential for patomorphological evaluation can be acquired with fine-needle aspiration biopsies (FNAB) controlled with CT and core-needle biopsy (CNB) under real-time CT fluoroscopy guidance. The purpose of this work is to carry out a retrospective analysis of the two methods with regards to their informativity, frequency and the kind of complications. MATERIAL/METHODS: From January, 2012 to May 2013, 76 core-needle biopsies of lung and mediastinum tumors were conducted and compared with 86 fine-needle aspiration biopsies(FNAB) of lung and mediastinum tumors, including 30 patients who underwent FNAB and were referred to CNB in order to specify the diagnosis. RESULTS: Complete histopathological diagnosis was made in 91% with the use of CNB and in 37% when FNAB was the chosen method. Early complications were observed in 32% patients who underwent BG and in group of 11% who underwent FNAB. Late complications, however, appeared in 29% patients after CNB and 13% after FNAB. In 24 cases CNB specified the complete diagnosis. CONCLUSIONS: Core-needle biopsy in comparison to fine-needle aspiration biopsy has more frequent rate of negligible complications, however, it offers higher diagnostic yield for diagnostic of lung and mediastinum neoplastic disease and allows for more precise diagnosis of focal lesions.

9.
Pol J Radiol ; 79: 75-8, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24744819

RESUMO

BACKGROUND: The most commonly used form of reporting doses in multislice computed tomography involves a CT dose index per slice and dose-length product for the whole series. The purpose of this study was to analyze the actual dose distribution in routine chest CT examination protocols using an antropomorphic phantom. MATERIAL/METHODS: We included in the analysis readings from a phantom filled with thermoluminescent detectors (Art Phantom Canberra) during routine chest CT examinations (64 MDCT TK LIGHT SPEED GE Medical System) performed using three protocols: low-dose, helical and angio-CT. RESULTS: Mean dose values (mSv) reported from anterior parts of the phantom sections in low-dose/helical/angio-CT protocols were as follows: 3.74; 16.95; 30.17; from central parts: 3.18; 14.15; 26.71; from posterior parts: 3.01; 12.47; 24.98 respectively. Correlation coefficients for mean doses registered in anterior parts of the phantom between low-dose/helical, low-dose/angio-CT and helical/angio-CT protocols were 0.49; 0.63; 0.36; from central parts: 0.73; 0.66; 0.83, while in posterior parts values were as follows: 0.06; 0.21; 0.57. CONCLUSIONS: The greatest doses were recorded in anterior parts of all phantom sections in all protocols in reference to largest doses absorbed in the anterior part of the chest during CT examination. The doses were decreasing from anterior to posterior parts of all sections. In the long axis of the phantom, in all protocols, lower doses were measured in the upper part of the phantom and at the very lowest part.

10.
Pol J Radiol ; 79: 1-5, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24454417

RESUMO

BACKGROUND: There are differences in the reference diagnostic levels for the computed tomography (CT) of the chest as cited in different literature sources. The doses are expressed either in weighted CT dose index (CTDIVOL) used to express the dose per slice, dose-length product (DLP), and effective dose (E). The purpose of this study was to assess the radiation dose used in Low Dose Computer Tomography (LDCT) of the chest in comparison with routine chest CT examinations as well as to compare doses delivered in low dose chest CT with chest X-ray doses. MATERIAL/METHODS: CTDIVOL and DLP doses were taken to analysis from routine CT chest examinations (64 MDCT TK LIGHT SPEED GE Medical System) performed in 202 adult patients with FBP reconstruction: 51 low dose, 106 helical, 20 angio CT, and 25 high resolution CT protocols, as well as 19 helical protocols with iterative ASIR reconstruction. The analysis of chest X-ray doses was made on the basis of reports from 44 examinations. RESULTS: Mean values of CTDIVOL and DLP were, respectively: 2.1 mGy and 85.1 mGy·cm, for low dose, 9.7 mGy and 392.3 mGy·cm for helical, 18.2 mGy and 813.9 mGy·cm for angio CT, 2.3 mGy and 64.4 mGy·cm for high resolution CT, 8.9 mGy. and 317.6 mGy·cm for helical ASIR protocols. Significantly lower CTDIVOL and DLP values were observed for low dose and high resolution CT versus the remaining CT protocols; doses delivered in CT ASIR protocols were also lower (80-81%). The ratio between medial doses in low dose CT and chest X-ray was 11.56. CONCLUSIONS: Radiation dose in extended chest LDCT with parameters allowing for identification of mediastinal structures and adrenal glands is still much lower than that in standard CT protocols. Effective doses predicted for LDCT may exceed those used in chest X-ray examinations by a factor of 4 to 12, depending on LDCT scan parameters. Our results, as well as results from other authors, suggest a possibility of reducing the dose by means of iterative reconstruction. Efforts towards further dose reduction which would permit replacing chest X-ray with low dose CT in certain research screening projects should be encouraged.

11.
Gastroenterol Res Pract ; 2013: 729279, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24302932

RESUMO

The aim of the study was to assess how realiable is differential diagnosis and prognosis for endoscopic treatment with MR signal characteristics as the qualitative parameter and magnetic resonance cholangiopancreatography (MRCP) images in cases of bile duct obstructions caused by solid masses. Material and Methods. Retrospective study of MR and MRCP images in 80 patients (mean age 58 ys) was conducted. Mean signal intensity ratio (SIR) from planar MR images and MRCP linear measurements were compared between benign and malignant lesions and in groups including the size and number of stents placed during ERCP (< 10 F <) in 51 cases in which ERCP was performed. Results. Significantly higher SIR values were encountered in malignant lesions in T2W images (r = 0,0003) and STIR T2W images (r = 0,0002). Malignant lesions were characterised by longer strictures (r = 0,0071) and greater proximal biliary duct dilatation (r = 0,0024). High significance for predicting ERCP conditions was found with mean SIR in STIR T2W images and stricture length. Conclusion. Probability of malignancy of solid lesions obstructing biliary duct increased with higher SIR in T2W images and with longer strictures. Passing the stricture during ERCP treatment was easier and more probable in cases of shorter strictures caused by lesions with higher SIR in STIR T2W images.

12.
Gastroenterol Res Pract ; 2013: 696423, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24454342

RESUMO

The aim of the study was to evaluate the usefulness of 18F-FLT PET/CT in the detection and differentiation of gastric cancers (GC). 104 consecutive patients (57 cases of adenocarcinoma tubulare (G2 and G3), 17 cases of mucinous adenocarcinoma, 6 cases of undifferentiated carcinoma, 14 cases of adenocarcinoma partim mucocellulare, and 10 cases of end stage gastric cancer) with newly diagnosed advanced gastric cancer were examined with FLT PET/CT. For quantitative and comparative analyses, the maximal standardized uptake value (SUVmax) was calculated for both the tumors and noninvaded gastric wall. Results. There were found, in the group of adenocarcinoma tubulare, SUVmax 1.5-23.1 (7.46 ± 4.57), in mucinous adenocarcinoma, SUVmax 2.3-10.3 (5.5 ± 2.4), in undifferentiated carcinoma, SUVmax 3.1-13.6 (7.28 ± 3.25), in adenocarcinoma partim mucocellulare, SUVmax 2-25.3 (7.7 ± 6.99), and, in normal gastric wall, SUVmax 1.01-2.55 (1.84 ± 0.35). For the level of 2.6 cut-off value between the normal wall and neoplasm FLT uptake from ROC analysis, all but five gastric cancers showed higher accumulation of FLT than noninfiltrated mucosa. Conclusion. Gastric cancer presents higher accumulation of 18F-FLT than normal, distended gastric mucosa. Significantly higher accumulation was shown in cancers better differentiated and with higher cellular density.

13.
Folia Morphol (Warsz) ; 61(1): 47-51, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-11905251

RESUMO

In this article the authors discuss whether or not diagnostic potential of MR cholangiopancreatography is strong enough to replace direct cholangiography in all cases. The pre-surgery analysis of a variety of pancreato-biliary disorders diagnosed using MRCP images is presented with the emphasising the importance of source images. Six cases of pancreato-biliary disorders are presented in which MRCP indicated the place of ductal stenosis as well as the morphologic variants or ductal uninspected shape which is critical for surgery or planned drainage. Coronal and axial MRCP source and MIP images were obtained with 0.5 T Gyroscan NT. Anomalies of the biliary or pancreatic ducts included two cases of choledochal cystic dilatation; two cases of aberrant biliary ducts, one case of gallbladder duct variant and a case of an additional pancreatic duct. In 3 out of 6 cases, the MRCP source images produced using the complementary method supplied more complete information concerning ductal junctions than the MIP images. Whereas in 3 out of 6 cases, both kinds of images were equally reliable. In 4 out of 6 cases, endoscopy was performed, and in 2 cases ERCP images were not diagnostic for ductal anatomy. However, full delineation of biliary and pancreatic ducts was complete in all MRCP images. MRCP within source images and maximum intensity projections show particular promise for the assessment of pancreato-biliary anomalies in order to reduce the number of higher-risk endoscopic interventions. The technique should be the method of choice in cases of suspected pancreato-biliary anomaly resulting from any imaging modality and is helpful for planning the optimal drainage method. In the long run this practice would reduce the number of ducts damaged during surgery.


Assuntos
Ductos Biliares/anormalidades , Imageamento por Ressonância Magnética/normas , Ductos Pancreáticos/anormalidades , Adulto , Idoso , Colangiografia , Colangite/patologia , Cisto do Colédoco/patologia , Colelitíase/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Pancreáticas/patologia , Reprodutibilidade dos Testes
14.
Folia Morphol (Warsz) ; 61(4): 291-7, 2002.
Artigo em Inglês | MEDLINE | ID: mdl-12725499

RESUMO

The purpose of this study was an evaluation of the ability of the multiphase spiral CT and MR imaging to localise focal liver lesions referring to specific hepatic segments. The authors studied prospectively 26 focal liver lesions in 26 patients who had undergone spiral CT and MRI before surgery. Multiphase spiral CT included non-contrast scans, hepatic arterial-dominant phase, portal venous--dominant phase and equilibrium phase. MRI was performed in all cases. The following sequences were performed: SE and TSE T1- and T2-weighted images, STIR and dynamic T1-weighted FFE study after i.v. administration of gadolinium (Gd-DTPA). The CT and MR scans were prospectively and independently reviewed by three radiologists for visualisation of hepatic and portal veins and segmental localisation of hepatic lesions. The authors used the right and left main portal veins along with transverse fissura, hepatic veins and gallbladder fossa as landmarks for the tumour localisation to specific hepatic segments. The primary segmental locations of the lesions were correctly determined with CT in 22 of 26 focal liver lesions (85%) and with MR imaging in 24 of 26 lesions (92%). The full extent of lesions was correctly described with sCT in 19 of 26 focal lesions and with MR in 21 of 26 tumours. MRI and CT were helpful preoperative tools for determining the segmental location of focal liver lesions and for planning the surgical approach.


Assuntos
Carcinoma Hepatocelular/diagnóstico , Hiperplasia Nodular Focal do Fígado/diagnóstico , Neoplasias Hepáticas/diagnóstico , Imageamento por Ressonância Magnética , Tomografia Computadorizada Espiral , Adulto , Idoso , Carcinoma Hepatocelular/irrigação sanguínea , Neoplasias Colorretais/diagnóstico , Neoplasias Colorretais/secundário , Equinococose Hepática/diagnóstico , Humanos , Fígado/irrigação sanguínea , Fígado/patologia , Neoplasias Hepáticas/irrigação sanguínea , Neoplasias Hepáticas/secundário , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Tomografia Computadorizada Espiral/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...